PG cable glands: thread and panel hole PG7–PG48 (DIN 40430), height, wrench flat, cable range + hole gauge
What mounting hole does a PG7, PG9, PG11, PG13.5, PG16 or PG21 cable gland need, and how tall is it? · Standard part · basis: Lapp technical table T21 (DIN 40430 PG thread and hole), Heyco brass PG cordgrip catalogue pages (height, thread length, wrench flat, cable range); hole gauge as a file, glands themselves numbers only
Also called: pg7 cable gland hole size, pg9 mounting hole, pg11 hole diameter, pg13.5 cable gland hole, pg16 hole size, pg21 cable gland dimensions, pg cable gland size chart, pg thread dimensions din 40430, cable gland hole gauge stl, pg29 hole size, pg cable gland wrench size, pg 13.5 thread diameter 20.4
Exact dimensions. True size, with no printing tolerance added.
- length
- 276.1 mm
- width
- 63.4 mm
- height
- 3.0 mm
Notes
- PG is the older cable-gland thread (DIN 40430 in Lapp's table), with the pitches below; it is not interchangeable with metric. D1 is the thread outer diameter, D2 the core diameter, D3 the panel hole. Lapp prints D3 as, e.g., '12.8 –0.2' and the value shown here is the number as printed with its tolerance symbol; the gauge file uses the printed D3.
- Heyco columns are the brass PG hub range (standard thread, series 4530–4554): clearance hole (a different series, Heyco's high-temp brass hubs, prints 12.6, 15.3, 18.7, 20.5, 22.6, 28.4, 37.2, 47.2 mm, about 0.1 mm larger), height as 'max O.A. length', thread length and wrench flat (hex across flats). The short-thread series 14530–14554 has its own height and thread length, shown in the columns (thread length 6.0 mm on PG 7–16). Cable range is per part number; each PG size comes in 2–4 clamp ranges, shown in order. Heyco's PG 13.5 prints 21.0 mm hole for two ranges and 20.4 for the 11.0–15.0 range.
- PG 19 and PG 25 are not in Lapp's table and Heyco's pages used here do not list them; VIOX's chart prints thread OD 25 and 32 mm for them but cites no standard, so they are left out. PG 42 and PG 48 have thread data only.
- Heyco's heights and wrench flats are for Heyco's glands; other makers' will differ. Use this as an envelope check, not as the gland drawing. Not published here: dome-nut shape, seal geometry, locknut size.
- Metric glands are on the page cable-glands-metric-thread. McMaster-Carr's cord-grip pages cover PG sizes (PG 16, PG 36 and PG 42 appear in its thread-size URLs) with per-part STEP; linked, not copied.
PG cable glands: thread and panel hole PG7–PG48 (DIN 40430), height… size chart
| PG size | thread OD D1 (mm) | pitch (mm) | core D2 (mm) | panel hole D3 (mm, Lapp) | Heyco hole (mm) | Heyco height, standard thread (mm) | Heyco height, short thread (mm) | thread length, standard (mm) | thread length, short (mm) | wrench flat (mm) | cable ranges (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PG 7 | 12.5 | 1.27 | 11.3 | 12.8 (–0.2) | 12.5 | 27.0 | 23.0 | 10.0 | 6.0 | 15 | 3.5–5.0 / 5.0–6.5 / 6.5–8.0 |
| PG 9 | 15.2 | 1.41 | 13.9 | 15.5 (–0.2) | 15.2 | 30.0 (32.0 for 8.0–10.5) | 26.0 (28.0 for 8.0–10.5) | 10.0 | 6.0 | 18 | 3.5–4.5 / 4.5–6.0 / 6.0–8.0 / 8.0–10.5 |
| PG 11 | 18.6 | 1.41 | 17.3 | 18.9 (–0.2) | 18.6 | 31.0 | 27.0 | 10.0 | 6.0 | 21 | 4.0–5.5 / 5.5–8.5 / 8.5–12.0 |
| PG 13.5 | 20.4 | 1.41 | 19.1 | 20.7 (–0.2) | 21.0 (20.4 for 11.0–15.0) | 31.0 (33.0 for 11.0–15.0) | 27.0 (29.0 for 11.0–15.0) | 10.0 | 6.0 | 24 | 6.0–8.0 / 8.0–11.0 / 11.0–15.0 |
| PG 16 | 22.5 | 1.41 | 21.2 | 22.8 (–0.2) | 22.5 | 33.0 | 29.0 | 10.0 | 6.0 | 24 | 6.0–8.0 / 8.0–11.0 / 11.0–15.0 |
| PG 21 | 28.3 | 1.588 | 26.8 | 28.6 (–0.2) | 28.3 | 40.0 | 35.5 | 12.0 | 7.5 | 30 | 9.5–12.5 / 12.5–16.0 / 16.0–20.5 |
| PG 29 | 37.0 | 1.588 | 35.5 | 37.4 (–0.3) | 37.3 | 40.0 | 36.0 | 12.0 | 8.0 | 38 | 16.0–19.0 / 19.0–23.0 / 23.0–27.5 |
| PG 36 | 47.0 | 1.588 | 45.5 | 47.4 (–0.3) | 47.6 | 47.0 | 47.0 | 15.0 | 8.0 | 50 | 21.5–26.0 / 26.0–30.5 / 30.5–35.0 |
| PG 42 | 54.0 | 1.588 | 52.5 | 54.4 (–0.3) | — | — | — | — | — | — | — |
| PG 48 | 59.3 | 1.588 | 57.8 | 59.7 (–0.3) | — | — | — | — | — | — | — |
Where the files are
Other publishers' files are linked, not hosted. "verify" = check the license at the link before commercial use.
Free files
★ Free files 1 parts. Generated by Xem Studio from the standard; threads are plain cylinders at major diameter. CC BY 4.0. index.json
| pg-gland-hole-gauge-pg7-pg36 | hole gauge plate, 276.1 × 63.4 × 3 mm, eight holes at the Lapp T21 (DIN 40430) hole diameters 12.8, 15.5, 18.9, 20.7, 22.8, 28.6, 37.4, 47.4 mm (PG 7, 9, 11, 13.5, 16, 21, 29, 36), smallest first, 8 mm between hole edges; plate thickness and spacing are Xem choices | STEP · STL |
https://xemstudio.com/mcp to Claude, ChatGPT, Cursor or any MCP client (free, no account, one minute) and it can look up exact sizes, mating fits and free STEP/STL from every chat.Plain text: sheet.txt · JSON: /api/geometry?object=cable-glands-pg-thread

Fits with





Questions
What hole for a PG9 cable gland?
Lapp prints a 15.5 mm panel hole for PG 9 (thread OD 15.2 mm); Heyco prints 15.2 mm for its brass PG 9.
What is the thread diameter of PG13.5?
20.4 mm outer diameter, 1.41 mm pitch (DIN 40430, Lapp T21).
What size wrench for PG16?
Heyco's brass PG 16 has a 24 mm wrench flat; other makers can differ.