Library › Tri-clamp & pipe › Pipe, tube & threads ·
PVC Schedule 40 and Schedule 80 pipe: OD, minimum wall and ID, 1/2 to 4 in
What are the OD, wall thickness and ID of Schedule 40 and Schedule 80 PVC pipe? · Standard part · basis: Westlake Pipe Sch 40 / Sch 80 table, JM Eagle spec sheet and McMaster-Carr Sch 80 pipe page agree; numbers only (Sch 40 pipe CAD on 'schedule-40-pipe')
Also called: schedule 80 pvc pipe od, sch 80 pvc wall thickness, schedule 80 pvc dimensions, pvc pipe wall thickness, 1 inch pvc id, 3/4 pvc pipe id, pvc pipe od chart, schedule 40 vs schedule 80 pvc, 2 inch pvc pipe id sch 80, 4 inch pvc pipe od, pvc pipe size chart mm, 1/2 pvc sch 80 wall
Exact dimensions. True size, with no tolerance added.
- sizes
- 9 in table
Notes
- Schedule 40 and Schedule 80 PVC share the outside diameter (the steel NPS OD); only the wall differs, so both fit the same sockets and fittings. Sch 80 is thicker inward: 1/2 in has a 0.109 in wall in Sch 40 and 0.147 in in Sch 80.
- Sources: OD, minimum wall and ID from Westlake Pipe's Sch 40 / Sch 80 table; OD and minimum wall repeated by JM Eagle's spec sheet (Rev 12) for all nine sizes (equal); Sch 80 minimum wall and ID repeated by McMaster-Carr's Schedule 80 pipe page. In every row Westlake's ID equals OD minus twice the minimum wall (to 0.0015 in). The Sch 40 sizes 1/2 to 2 in match the existing 'schedule-40-pipe' page (OD 21.34 to 60.33 mm, walls 2.77 to 3.91 mm).
- Minimum wall, not nominal: real pipe is thicker and OD has a tolerance. The ID is a calculated value, not a control dimension.
- STEP/STL for Sch 40 pipe stubs (1/2 to 2 in) are on 'schedule-40-pipe'; no pipe files are repeated here. Left out: Sch 40 / 80 OD tolerances and sizes under 1/2 in and over 4 in (in the same tables, not asked), Schedule 120, and pressure ratings (differ by maker and temperature).
PVC Schedule 40 and Schedule 80 pipe: OD, minimum wall and ID, 1/2… size chart
| nominal pipe size, in | OD, in (mm) | Sch 40 min wall, in (mm) | Sch 40 ID, in (mm) | Sch 80 min wall, in (mm) | Sch 80 ID, in (mm) |
|---|---|---|---|---|---|
| 1/2 | 0.840 (21.34) | 0.109 (2.77) | 0.622 (15.80) | 0.147 (3.73) | 0.546 (13.87) |
| 3/4 | 1.050 (26.67) | 0.113 (2.87) | 0.824 (20.93) | 0.154 (3.91) | 0.742 (18.85) |
| 1 | 1.315 (33.40) | 0.133 (3.38) | 1.049 (26.64) | 0.179 (4.55) | 0.957 (24.31) |
| 1-1/4 | 1.660 (42.16) | 0.140 (3.56) | 1.380 (35.05) | 0.191 (4.85) | 1.278 (32.46) |
| 1-1/2 | 1.900 (48.26) | 0.145 (3.68) | 1.610 (40.89) | 0.200 (5.08) | 1.500 (38.10) |
| 2 | 2.375 (60.32) | 0.154 (3.91) | 2.067 (52.50) | 0.218 (5.54) | 1.939 (49.25) |
| 2-1/2 | 2.875 (73.02) | 0.203 (5.16) | 2.469 (62.71) | 0.276 (7.01) | 2.323 (59.00) |
| 3 | 3.500 (88.90) | 0.216 (5.49) | 3.068 (77.93) | 0.300 (7.62) | 2.900 (73.66) |
| 4 | 4.500 (114.30) | 0.237 (6.02) | 4.026 (102.26) | 0.337 (8.56) | 3.826 (97.18) |
Where the files are
Other publishers' files are linked, not hosted. "verify" = check the license at the link before commercial use.
| Westlake Pipe | Sch 40 / Sch 80 pressure pipe: OD, minimum wall, ID, 1/2 to 18 in | web | Publisher's page; dimensions are facts |
| JM Eagle | Pressure-rated PVC pipe spec sheet (Rev 12): Sch 40 and Sch 80 average OD and minimum wall | web | Publisher's page; dimensions are facts |
| McMaster-Carr | PVC (Schedule 80) pipe, unthreaded (free STEP/IGES per part, for your own design use; no redistribution) | STEP, IGES, PDF | McMaster-Carr site terms: personal design use, no redistribution verify |
| McMaster-Carr | PVC (Schedule 80) pipe fittings (free STEP/IGES per part, for your own design use; no redistribution) | STEP, IGES, PDF | McMaster-Carr site terms: personal design use, no redistribution verify |
| McMaster-Carr | PVC (Schedule 40) fittings and pipe, UV-resistant (socket-connect elbows, tees, couplings) (free STEP/IGES per part, for your own design use; no redistribution) | STEP, IGES, PDF | McMaster-Carr site terms: personal design use, no redistribution verify |
Xem scan
File coming
No downloadable true-size file yet: the published figures do not fix the whole shape, and Xem never guesses a number. A measured scan is planned; request it and it moves up.
https://xemstudio.com/mcp to Claude, ChatGPT, Cursor or any MCP client (free, no account, one minute) and it can look up exact sizes, mating fits and free STEP/STL from every chat.Plain text: sheet.txt · JSON: /api/geometry?object=pvc-schedule-40-80-pipe-od-and-wall
Fits with




Questions
What is the OD of 1 in Schedule 80 PVC pipe?
1.315 in (33.40 mm), the same as Schedule 40; Sch 80 has a 0.179 in (4.55 mm) minimum wall and a 0.957 in (24.31 mm) ID.
What is the difference between Sch 40 and Sch 80 PVC?
Wall thickness only: the OD is identical, so the same socket fittings fit. 1/2 in is 0.109 in thick in Sch 40 and 0.147 in in Sch 80.
What is the ID of 2 in Schedule 40 PVC?
2.067 in (52.50 mm) with a 0.154 in minimum wall; Schedule 80 is 1.939 in (49.25 mm).