Library › Tri-clamp & pipe › Pipe, tube & threads ·

SAE J518 / ISO 6162 4-bolt flange ports, Code 61 and Code 62: bolt spacing, port, bolt thread, O-ring + port-pattern plates

What is the bolt spacing, bolt size and O-ring of an SAE Code 61 or Code 62 4-bolt flange port? · Standard part · basis: Parker 4400 flange port table (A, B, C, D), cross-checked against Hydroscand's SAE flange table, hoseandfittings' bolt spacing and O-ring table, MFCP's bolt table and Parker's TFD O-ring sheet; ten port-pattern plates as files

Also called: code 61 flange bolt spacing, code 62 flange dimensions, sae 4 bolt flange bolt pattern, sae j518 flange o-ring size, code 61 3/4 flange bolt spacing, code 62 1 inch flange dimensions, iso 6162-1 bolt size, sae flange o-ring 2-214, hydraulic split flange bolt pattern, code 61 vs code 62, sae flange port stl, flange block bolt hole pattern, 5/16-18 code 61 1/2 flange

Exact dimensions. Every file is drawn at true size with no tolerance added. The holes and pins that meet another part are listed below under Mating features, with the fit each joint needs; open those by your process's clearance before making the part. Mating features

length
129.9 mm
width
77.5 mm
height
6.0 mm

Notes

  • SAE J518 (ISO 6162-1 for Code 61, ISO 6162-2 for Code 62) 4-bolt split flange: a rectangle of four bolts around a central port; the O-ring sits in the flange head and seals on the port-block face. Code 61 (standard series) and Code 62 (high-pressure series) have the same port bore per dash size but different bolt spacing and bolt size, so the port blocks do not interchange. Pressure ratings are left out on purpose: they depend on size, maker and flange kit (the sources read give different tables).
  • Spacing. Parker's 4400 catalog prints a port table with the letters A (dia max), B (thread), C and D (each in inches ± 0.010 and in mm ± 0.25): C is the long bolt-to-bolt distance and D the short one (the 1/2 in Code 61 row: C 1.50 in / 38.10 mm, D 0.68 in / 17.47 mm). Hydroscand's SAE flange table (letters not defined on its page) lists the long distance as 38.10 and the short as 17.38 for the same size; the two agree within Parker's ± 0.25 mm for every Code 61 size -8 to -32. The 'long / short' column pair shows Hydroscand's values for the same size, and its extra Code 61 sizes -40 to -80 and Code 62 -8.
  • Code 62 -12 (3/4 in) disagrees: Parker 4400 prints 22.35 mm for the short spacing (0.88 in) and 47.75 mm for the long (labelled 2.00 in; 2.00 in is 50.8 mm), Hydroscand prints 23.80 / 50.80. The Parker long value does not match its own inch figure, so both are shown and no plate is drawn for that size. Code 62 -8 is not in the Parker 4400 table: its spacing (40.49 / 18.24 mm) is Hydroscand's alone (the long spacing agrees with hoseandfittings' 1-19/32 in = 40.5 mm), and it has no printed A dia, so no plate is drawn.
  • Bolts: inch thread from Parker's flange kits and MFCP (the two agree for every size shown); metric ISO 6162 screw from MFCP, which marks Code 61 -32 (M12) and Code 62 -20 (M14) as not meeting ISO 6162. Hydroscand's inch column for Code 61 -48 (3 in) says 1/2, while Parker's kit and MFCP say 5/8-11: shown as 5/8-11 with the difference noted in the table. O-ring: AS568 2-2xx dash numbers from hoseandfittings and Parker's O-ring sheet (ID × W in inches, Parker); 2-241 and 2-245 (3 1/2 and 4 in) are hoseandfittings' alone.
  • Files: ten port-pattern plates (Code 61 -8, -12, -16, -20, -24, -32 and Code 62 -16, -20, -24, -32): the central hole is the printed 'A dia max' diameter, the four holes are the bolt's nominal major diameter as a plain hole (tap or clear it as you need), at Parker's C × D spacing. Plate size, thickness (6 mm) and corner radius are Xem's choices. The flange head, O-ring groove and flange thickness are not drawn: the sources read give no groove dimensions.
  • McMaster-Carr sells Code 61 and 62 split flanges, flange kits and flange adapters with per-part STEP; its identification page is linked, not copied. Parker's catalog pages (linked) are the maker source.

SAE J518 / ISO 6162 4-bolt flange ports, Code 61 and Code 62: bolt… size chart

codedashflange sizeport A dia max (mm)bolt thread (Parker)bolt spacing C (long)bolt spacing D (short)Hydroscand long / short (mm)O-ring (AS568, ID × W in)bolt: inch / ISO 6162 metric (MFCP)
Code 61-81/2 in≤ 13 (A dia max)5/16-181.50 in / 38.10 mm0.68 in / 17.47 mm38.10 / 17.382-210 (0.734 × 0.139 in)5/16-18 / M8
Code 61-123/4 in≤ 19 (A dia max)3/8-161.88 in / 47.63 mm0.87 in / 22.22 mm47.63 / 22.232-214 (0.984 × 0.139 in)3/8-16 / M10
Code 61-161 in≤ 25 (A dia max)3/8-162.06 in / 52.37 mm1.03 in / 26.18 mm52.37 / 26.192-219 (1.296 × 0.139 in)3/8-16 / M10
Code 61-201 1/4 in≤ 32 (A dia max)7/16-142.31 in / 58.72 mm1.18 in / 30.17 mm58.72 / 30.182-222 (1.484 × 0.139 in)7/16-14 / M10
Code 61-241 1/2 in≤ 38 (A dia max)1/2-132.75 in / 69.85 mm1.40 in / 35.71 mm69.85 / 35.712-225 (1.859 × 0.139 in)1/2-13 / M12
Code 61-322 in≤ 51 (A dia max)1/2-133.06 in / 77.77 mm1.68 in / 42.87 mm77.77 / 42.882-228 (2.234 × 0.139 in)1/2-13 / M12 (not ISO 6162)
Code 61-402 1/2 in—1/2-13——88.90 / 50.802-232 (2.734 × 0.139 in)1/2-13 / M12
Code 61-483 in—5/8-11 (Hydroscand lists 1/2 UNC)——106.38 / 61.932-237 (3.359 × 0.139 in)5/8-11 / M16
Code 61-563 1/2 in—5/8-11——120.65 / 69.852-2415/8-11 / M16
Code 61-644 in—5/8-11——130.18 / 77.772-2455/8-11 / M16
Code 61-805 in—5/8-11——152.40 / 92.08—5/8-11 / M16
Code 62-123/4 in≤ 19 (A dia max)3/8-162.00 in / 47.75 mm0.88 in / 22.35 mm (Parker 4400 prints 22.35 / 47.75: out of line with 0.938 / 2.00 in; both shown, no plate)50.80 / 23.802-214 (0.984 × 0.139 in)3/8-16 / M10
Code 62-161 in≤ 25 (A dia max)7/16-142.25 in / 57.15 mm1.09 in / 27.76 mm57.15 / 27.762-219 (1.296 × 0.139 in)7/16-14 / M12
Code 62-201 1/4 in≤ 32 (A dia max)1/2-132.63 in / 66.67 mm1.25 in / 31.75 mm66.68 / 31.752-222 (1.484 × 0.139 in)1/2-13 / M14 (not ISO 6162)
Code 62-241 1/2 in≤ 38 (A dia max)5/8-113.13 in / 79.37 mm1.43 in / 36.49 mm79.38 / 36.502-225 (1.859 × 0.139 in)5/8-11 / M16
Code 62-322 in≤ 51 (A dia max)3/4-103.81 in / 96.82 mm1.75 in / 44.45 mm96.82 / 44.452-228 (2.234 × 0.139 in)3/4-10 / M20
Code 62-81/2 in— (not in Parker 4400 table)5/16-18— (Hydroscand 40.49; hoseandfittings 1.59 in)— (Hydroscand 18.24)40.49 / 18.242-210 (0.734 × 0.139 in)5/16-18 / M8

Mating features

Drawn at the exact size. Open press, slide, run and socket features by your process's clearance (tolerances by process); leave designed gaps and clamp fits as drawn.

featureexactmates withfitfiles
port hole (A dia max as printed)Ø13 / 19 / 25 / 32 / 38 / 51 mm for flange sizes -8 / -12 / -16 / -20 / -24 / -32 (Code 62 from -16: Ø25 / 32 / 38 / 51)port bore in the flange head and the tube or hose-end stub bore; the O-ring (AS568 2-210 to 2-228) seals on the flange head face, not on this holedesignedflange-port-plate-code*
four bolt holes at the nominal bolt major (plain hole for a tapped thread)long × short spacing and thread per size, e.g. Code 61 -12: 47.63 × 22.22 mm, 3/8-16; Code 62 -24: 79.37 × 36.49 mm, 5/8-11SAE J518 flange screws (inch UNC grade 8) or ISO 6162 metric screws; tap the thread in the port block or drill the clearance in the split flangedesignedflange-port-plate-code*

Where the files are

Other publishers' files are linked, not hosted. "verify" = check the license at the link before commercial use.

Parker Hannifin, Hydraulic Hose Products Division (4400 catalog pages, hosted by Triad Technologies)Code 61 and Code 62 4-bolt flange port tables, SAE J518: A dia max, B thread, C and D bolt spacing (in and mm), flange kits (O-ring, bolts)webMaker catalog; numbers only
HydroscandSAE flange dimensions: Code 61 (3000) and Code 62 (6000), size, A, B, nut dimension metric and UNC, D, EwebDistributor page; numbers only. The page does not define its letters
hoseandfittings.comFour bolt flange: bolt spacing and O-ring by dash size, Code 61 and Code 62webDistributor page; numbers only
MFCP (Parker distributor)Parker flange connection assembly: Code 61 and Code 62 bolt sizes, inch (J518) and metric (ISO 6162)webDistributor page; numbers only
Parker Tube Fittings Division (hosted by Wilson Company)O-rings and seals: ORFS, SAE boss, ISO 6149, SAE 4-bolt flange O-ring sizes (ID, W)webMaker catalog pages; numbers only
McMaster-CarrO-ring flanges (how to identify and measure; Code 61 / 62 split flanges) (free STEP/IGES per part, for your own design use; no redistribution)STEP, IGES, PDFMcMaster-Carr site terms: personal design use, no redistribution verify

Free files

★ Free files 10 parts. Generated by Xem Studio from the standard; threads are plain cylinders at major diameter. CC BY 4.0. index.json

flange-port-plate-code61-8-5_16x18SAE J518 Code 61 -8 port pattern plate, 60.0 × 39.4 × 6 mm: central port hole Ø13 (A dia max, as printed), four bolt holes Ø7.94 (nominal major of 5/16-18, a plain hole in place of the thread) on 38.10 (long, X) × 17.47 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code61-12-3_8x16SAE J518 Code 61 -12 port pattern plate, 71.2 × 45.7 × 6 mm: central port hole Ø19 (A dia max, as printed), four bolt holes Ø9.52 (nominal major of 3/8-16, a plain hole in place of the thread) on 47.63 (long, X) × 22.22 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code61-16-3_8x16SAE J518 Code 61 -16 port pattern plate, 75.9 × 49.7 × 6 mm: central port hole Ø25 (A dia max, as printed), four bolt holes Ø9.52 (nominal major of 3/8-16, a plain hole in place of the thread) on 52.37 (long, X) × 26.18 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code61-20-7_16x14SAE J518 Code 61 -20 port pattern plate, 83.8 × 55.3 × 6 mm: central port hole Ø32 (A dia max, as printed), four bolt holes Ø11.11 (nominal major of 7/16-14, a plain hole in place of the thread) on 58.72 (long, X) × 30.17 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code61-24-1_2x13SAE J518 Code 61 -24 port pattern plate, 96.5 × 62.4 × 6 mm: central port hole Ø38 (A dia max, as printed), four bolt holes Ø12.70 (nominal major of 1/2-13, a plain hole in place of the thread) on 69.85 (long, X) × 35.71 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code61-32-1_2x13SAE J518 Code 61 -32 port pattern plate, 104.5 × 69.6 × 6 mm: central port hole Ø51 (A dia max, as printed), four bolt holes Ø12.70 (nominal major of 1/2-13, a plain hole in place of the thread) on 77.77 (long, X) × 42.87 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code62-16-7_16x14SAE J518 Code 62 -16 port pattern plate, 82.3 × 52.9 × 6 mm: central port hole Ø25 (A dia max, as printed), four bolt holes Ø11.11 (nominal major of 7/16-14, a plain hole in place of the thread) on 57.15 (long, X) × 27.76 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code62-20-1_2x13SAE J518 Code 62 -20 port pattern plate, 93.4 × 58.5 × 6 mm: central port hole Ø32 (A dia max, as printed), four bolt holes Ø12.70 (nominal major of 1/2-13, a plain hole in place of the thread) on 66.67 (long, X) × 31.75 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code62-24-5_8x11SAE J518 Code 62 -24 port pattern plate, 109.2 × 66.4 × 6 mm: central port hole Ø38 (A dia max, as printed), four bolt holes Ø15.88 (nominal major of 5/8-11, a plain hole in place of the thread) on 79.37 (long, X) × 36.49 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
flange-port-plate-code62-32-3_4x10SAE J518 Code 62 -32 port pattern plate, 129.9 × 77.5 × 6 mm: central port hole Ø51 (A dia max, as printed), four bolt holes Ø19.05 (nominal major of 3/4-10, a plain hole in place of the thread) on 96.82 (long, X) × 44.45 (short, Y) mm; plate size, thickness and corner radius are Xem choicesSTEP · STL
Let your AI pull this. Add https://xemstudio.com/mcp to Claude, ChatGPT, Cursor or any MCP client (free, no account, one minute) and it can look up exact sizes, mating fits and free STEP/STL from every chat.
Set it up →

Plain text: sheet.txt · JSON: /api/geometry?object=sae-j518-iso-6162-4-bolt-flange-ports

SAE J518 / ISO 6162 4-bolt flange ports, Code 61 and Code 62: bolt spacing, port, bolt thread, O-ring + port-pattern plates, isometric render of a generated part
Render of flange-port-plate-code61-32-1_2x13 from the free STEP; not to scale.

Fits with

Questions

What is the bolt pattern of a Code 61 1 in flange?

Parker's 4400 table prints C 2.06 in / 52.37 mm (long) by D 1.03 in / 26.18 mm (short), 3/8-16 bolts, port A dia max 25 mm; the O-ring is AS568 2-219.

Do Code 61 and Code 62 flanges interchange?

No. The same dash size has the same port bore but different bolt spacing and bolt size: Code 61 -16 is 52.37 × 26.18 with 3/8-16, Code 62 -16 is 57.15 × 27.76 with 7/16-14.

What O-ring does an SAE 4-bolt flange use?

An AS568 2-2xx O-ring: 2-210 for -8, 2-214 for -12, 2-219 for -16, 2-222 for -20, 2-225 for -24, 2-228 for -32, 2-232 for -40 and 2-237 for -48 (hoseandfittings and Parker agree).