Library › Electronic components › Connectors ·

NEMA plug and receptacle configurations: 1-15, 5-15, 5-20, 6-15, 6-20, 14-30, 14-50, L5-30, L14-30 (blade numbers as published)

What are the blade sizes and spacing of a NEMA 5-15 plug, and what do 5-20, 6-15, 14-50 and L5-30 look like? · Standard part · basis: ANSI/NEMA WD 6 as summarised by Wikipedia, worldstandards.eu, NEMA's wiring devices FAQ, Hubbell Bryant and distributor listings; numbers only, no files

Also called: nema 5-15 plug dimensions, nema 5-15p blade size, us plug blade width and spacing, nema 14-50 plug dimensions, nema l5-30 dimensions, nema 6-15 blade spacing, nema 1-15 vs 5-15, nema 5-20 vs 5-15, type b plug dimensions mm, nema wd 6, nema l14-30 vs 14-30, us plug ground pin diameter, nema plug configuration chart, us power plug blade length, nema 14-30 vs 14-50

Exact dimensions. Every file is drawn at true size with no tolerance added. The holes and pins that meet another part are listed below under Mating features, with the fit each joint needs; open those by your process's clearance before making the part. Mating features

sizes
11 in table

Notes

  • NEMA configuration names read as: a number for the family (1 = 125 V no ground, 5 = 125 V grounded, 6 = 250 V grounded, 14 = 125/250 V four-wire), a hyphen, the amps; an L in front means locking (twist-lock). P is the plug (male), R the receptacle (female) and C the cord connector.
  • The dimensional standard for all of them is ANSI/NEMA WD 6, which is sold, not free. The numbers on this page are the ones that public summaries and maker pages print; the sources read give a full set of blade numbers for the 1-15 and 5-15 only. Every blank in the table is a number Xem could not read in a source, not a missing blade.
  • Maker drawings were read for the 5-15P (Pass & Seymour PS5266 and the Turnlok L630 sheet): they print overall housing numbers such as 2.791, 1.752, 1.516 and 1.358 in without saying which length each is, so none is used. Hubbell's 14-50 housing numbers have the same problem.
  • Disagreement kept: the 5-15 ground pin is 3.2 mm longer than the power blades on Wikipedia and worldstandards.eu, 4 mm longer on the Museum of Plugs and Sockets page. dimensions.com adds a 21.4 mm earth pin length and a 6.3 to 7.9 mm 'height' for the power blades without saying what they are measured from; those are not used.
  • No receptacle slot sizes, contact positions, or plug body outlines were read, so no file is drawn: a plug drawn from the blade numbers alone would not be the part you can buy. Wall plate and box numbers are on the pages wall-plate-duplex-us, wall-plate-toggle-us and device-boxes-us.
  • A polarised 1-15P fits a 5-15R: the receptacle has the same wider neutral slot (Wikipedia). IEC 60320 appliance couplers (C13 / C14 and others) are on their own page.

NEMA plug and receptacle configurations: 1-15, 5-15, 5-20, 6-15… size chart

configurationpoles / wiresrating as publishedblade or pin numbers as publishedsource
1-15P plug2 / 2 (hot, neutral, no ground)15 A, 125 V maxTwo flat blades, 1/4 in (6.4 mm) wide (6.3 mm on worldstandards.eu), 0.06 in (1.5 mm) thick, 5/8 to 23/32 in (15.9 to 18.3 mm) long, 1/2 in (12.7 mm) apart; polarised neutral blade 5/16 in (7.9 mm) wideWikipedia; worldstandards.eu
5-15P plug / 5-15R receptacle2 / 315 A, 125 V (Pass & Seymour PS5266 datasheet: 15 A, 125 V, 2-pole 3-wire)Power blades as on the 1-15P (worldstandards.eu: 6.3 wide, 1.5 thick, 15.9 to 18.3 long, 12.7 apart). Ground pin Ø3/16 in (4.8 mm), round or U-shaped; 1/8 in (3.2 mm) longer than the power blades (Wikipedia, worldstandards.eu) but 4 mm longer in the Museum of Plugs and Sockets; offset 15/32 in (11.9 mm) from the blades, 1/4 in (6.4 mm) edge to edge (Wikipedia)Wikipedia; worldstandards.eu; dimensions.com; plugsocketmuseum.nl
5-20P plug2 / 320 A, 125 V (amps from the naming rule; 125 V from Wikipedia's table)Neutral blade turned 90 degrees; its inner edge is about 1/2 in (12.7 mm) from the hot blade. No other numbers in the sources readWikipedia
6-15P plug2 / 315 A, 250 V maxCollinear horizontal blades 23/32 in (18.3 mm) centre to centre, plus a ground pin. Blade width and thickness not in the sources readWikipedia
6-20P plug2 / 320 A, 250 V maxOne blade turned 90 degrees. No numbers in the sources readWikipedia
14-30P plug3 / 430 A; voltage not settled: Wikipedia's table prints 250 V max for the 14-series rows, distributor listings for 14-50 and L14-30 print 125/250 VL-shaped neutral blade. No numbers in the sources readWikipedia
14-50P plug3 / 4 (Hubbell: 3-pole 4-wire)50 A, 125/250 V AC (Hubbell Bryant catalog)Straight neutral blade, sized so that it does not mate with a 14-30 receptacle. Hubbell's plug housing numbers (A 2.88 in, B 4.13 in) are printed without a legend, so they are not usedWikipedia; Hubbell Bryant A-27
5-30 and 5-50 plugs (the bigger 5-series)2 / 330 A and 50 A, 125 V1 in (25.4 mm) between the power pins; the 5-30 also has an L-shaped neutral bladeWikipedia (quoting the NEMA locking configuration chart)
L5-30P locking plug2 / 330 A, 125 V (amps from the naming rule)Curved-blade, twist-locking. No numbers in the sources readWikipedia
L14-30P locking plug3 / 430 A, 125/250 V AC, single phase (distributor listing title)Curved-blade, twist-locking. No numbers in the sources readZoro listing; Wikipedia
any plug (duplex receptacle spacing)--Maximum plug diameter 1.531 in (38.9 mm, computed) so that a plug fits in each half of a duplex receptacle; the FAQ says blade profiles are specified in UL 1659NEMA wiring devices FAQ

Mating features

Drawn at the exact size. Open press, slide, run and socket features by your process's clearance (tolerances by process); leave designed gaps and clamp fits as drawn.

featureexactmates withfitfiles
1-15P / 5-15P hot blade6.3 to 6.4 wide × 1.5 thick, 12.7 between blades5-15R receptacle slots (slot sizes not published in the sources read)designedall
1-15P polarised neutral blade7.9 wide (5/16 in)the wider neutral slot of a 5-15R (Wikipedia)designedall
5-15P ground pinØ4.8 (3/16 in), 3.2 longer than the blades (4 in one source), offset 11.95-15R ground hole (size not published in the sources read)designedall

Where the files are

Other publishers' files are linked, not hosted. "verify" = check the license at the link before commercial use.

ANSI / NEMAANSI/NEMA WD 6 Wiring Devices - Dimensional Specifications (the standard behind every NEMA configuration; sold, not free)webStandards body's page; dimensions are facts, the standard itself is paid
WikipediaNEMA connector: rating table and the blade numbers quoted for 1-15, 5-15, 5-20, 5-30, 5-50, 6-15webPublisher's page; dimensions are facts
World Standards (worldstandards.eu)Plugs and sockets of types A and B (NEMA 1-15 and 5-15): blade width, thickness, length, spacing, earth pinwebPublisher's page; dimensions are facts
dimensions.comType B plug and socket: blade and earth pin numbers (agrees with the page above on spacing and earth pin)webPublisher's page; dimensions are facts
Museum of Plugs and SocketsNorth American plugs: the earth pin of the 5-15P is 4 mm longer than the hot / neutral bladeswebPublisher's page; dimensions are facts
NEMA Wiring DevicesWiring Devices Frequently Asked Questions (WD 11-2023): maximum plug diameter 1.531 in; blade profiles are in UL 1659webPublisher's page; dimensions are facts
Hubbell BryantCatalog page A-27: 50 A straight blade devices (5-50, 6-50, 10-50, 14-50, 15-50, 18-50), ratings and housing dimensionswebPublisher's page; dimensions are facts
Pass & Seymour / Legrand (RS copy)PS5266 straight blade plug, NEMA 5-15P, 15 A 125 V, 2-pole 3-wire (drawing numbers are not labelled)webPublisher's page; dimensions are facts
Zoro (distributor listing)Locking plug L14-30P, 30 A, 125/250 V AC, single phase, 3 polewebPublisher's page; dimensions are facts
McMaster-CarrPanel-mount NEMA receptacles (per-part CAD; no maker CAD page was reached) (free STEP/IGES per part, for your own design use; no redistribution)STEP, IGES, PDFMcMaster-Carr site terms: personal design use, no redistribution verify

Xem scan

File coming

No downloadable true-size file yet: the published figures do not fix the whole shape, and Xem never guesses a number. A measured scan is planned; request it and it moves up.

Let your AI pull this. Add https://xemstudio.com/mcp to Claude, ChatGPT, Cursor or any MCP client (free, no account, one minute) and it can look up exact sizes, mating fits and free STEP/STL from every chat.
Set it up →

Plain text: sheet.txt · JSON: /api/geometry?object=nema-plug-receptacle-configurations

length
Schematic, not to scale.

Fits with

Questions

How far apart are the blades on a US 5-15 plug?

1/2 in (12.7 mm) between the power blades; the ground pin is offset 11.9 mm (15/32 in) from them.

How big is the ground pin on a NEMA 5-15 plug?

Ø3/16 in (4.8 mm), round or U-shaped; 3.2 mm (1/8 in) longer than the blades on two sources, 4 mm on a third.

What is the difference between NEMA 5-15 and 5-20?

The 5-20 has its neutral blade turned 90 degrees (a T slot), with the inner edge about 1/2 in (12.7 mm) from the hot blade; the 5-20 is rated 20 A.

What does the L in NEMA L5-30 mean?

Locking (twist-lock): curved blades; the 30 is the amp rating.